Fluke 116 Digital HVAC Multimeter (116)
- Operating temperature -10°C to 50°C.
- Storage temperature -40°C to 60°C.
- Battery type 9 volt Alkaline, IEC 6LR61.
- Battery life 400 hours typical, without backlight.

Fluke 116 Digital HVAC Multimeter (116)
Request a Call Back
- Ask a Question

Fluke 116 Digital HVAC Multimeter (116)
Ask a Question
The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
FEATURES OF 116 DIGITAL HVAC MULTIMETER (116)
- Measures resistance, continuity, frequency, and capacitance.
- Provides Min/Max/Average to record signal fluctuations.
- Comes with a holster with probe holders for easy storage.
- Features a compact ergonomic design for one-handed operation.
- Fits into optional ToolPak™ magnetic hanger for hands-free operation.
SPECIFICATION OF 116 DIGITAL HVAC MULTIMETER (116)
| Name | Details | |
| Model | 116 | |
| Brand | Fluke | |
| Origin | Japan | |
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600V | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to 50°C | |
| Storage temperature | -40°C to 60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] [counts]): 0.5% 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V |
| Accuracy | ±([% of reading] [counts]): 0.5% 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% 3 (DC, 45 Hz to 500 Hz)4.0% 3 (500 Hz to 1 kHz) | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) | |
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
| Accuracy | 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer. | |
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% 1 | |
| Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% 2 | |
| Diode Test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF |
| Accuracy | 1.9% 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% 20% | |
| Lo-Z Capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% 2 typical | |
| Temperature²(Type-K thermocouple) | Range/resolution | -40°C to 400°C / 0.1°C |
| Accuracy | 1% 10² | |
| Range/resolution | -40°F to 752°F / 0.2°F | |
| Accuracy | 1% 18² | |
| AC μA true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.5% 3 | |
| DC μamps | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.0% 2 | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Based on 0 reviews
0.00
Overall
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
Be the first to review “Fluke 116 Digital HVAC Multimeter (116)” Cancel reply
SKU: STE0154
Category: New Bangladesh
Close
Categories
- Agriculture Equipment
- Business & Industry
- Electrical & Electronics
- Garments Machinery
- Meter Equipment
- Ammonia Gas Detector
- Anemometer
- Carbon Dioxide Detector
- Carbon Monoxide Detector
- Carbon Monoxide Meter
- Clamp Meter
- Coating Thickness Gauge
- Conductivity Meter
- Differential Pressure Meter
- Digital Multimeter
- Digital Tachometer
- Digital Thermometer
- Film Thickness Gauge
- Gas Detector
- Gas Leak Detector
- Gas Monitor
- Grain Moisture Meter
- Humidity Temperature Meter
- Infrared Thermal Imager
- Infrared Thermometer
- Insulation Resistance Tester
- Laser Distance Meter
- Lux Meter
- Metal Detector
- Moisture Meter
- Oxygen Monitor
- PH Meter
- Sound Level Meter
- TDS Meter
- Ultrasonic Thickness Gauge
- Underground Metal Detector
- Vibration Meter
- Voltage Detector
- Wood Moisture Meter
- Office Equipment
- Print and Packaging
- Safety Equipment
- Boiler Suit
- Eye Wash Station
- Fire Extinguisher
- Floor Sweeper
- Hand Gloves
- Hand Traffic Light
- Industrial Spill Kit
- Life Buoy Ring
- Marking Tape
- Metal Detector
- Road Con
- Safety Belt
- Safety Cabinet
- Safety Ear Muff
- Safety Goggles
- Safety Helmet
- Safety Mask
- Safety Shoe
- Safety Shower
- Search Mirror
- Spill Pallet
- Textile Lab Machinery
- Weight Scale and Balance
- Fashion & Beauty
- Food & Essentials
- Hobbies, Sports & Kids
- Home & Living
- Home & Property
- Mobile & Electronics
- Pet & Animals
- Vehicle & Parts
Tags
- Artificial Models
- Beakers
- Biofloc Equipment List
- Biofloc Solution
- Buffer Solution
- Calipers
- Clamp Meters
- Conductivity Meter
- Conical Flask
- Digital Balance
- Digital Humidity Meter
- Digital PH Meter
- Digital Weighing Scale
- EC Meter
- Garments and Textile
- General ICs
- Glass Beaker
- Glass Bottle
- Glass Conical Flask
- Glass Magnifier
- Glass Measuring Cylinder
- Hand Gloves
- IC
- Integrated Circuits
- Lab Chemicals
- Lab Cylinder
- Lab Glassware
- Lab Reagents
- Laser Distance Meter
- Magnifying Glasses
- Measuring Cylinder
- Multimeters
- PH Meters
- PH Tester
- Reagent Bottle
- Safe and Safety
- Slide Calipers
- TDS Meters
- TDS Tester
- Temperature Meter
- Transistors
- Vernier Caliper
- Water Multi-Parameter
- Water Technology & Research
- Water Test Kit
Related Products
Hanna Edge® Dedicated Conductivity/TDS/Salinity Meter (HI2003)
Read more
- Salinity (% NaCl) Calibration Single point witd HI 7037L Standard.
- Salinity (PSU) Range 2.00 to 42.00 PSU.
- Salinity (PSU) Resolution 0.01 PSU.
- Salinity (PSU) Accuracy ±1% of reading.
Hanna PH Meter Multiparameter (HI2020)
Read more
- pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV.
- pH Temperature Compensation ATC.
- pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV.
- pH Resolution 0.001 pH, 0.01 pH, 0.1 mV.
CARER Electric Forklift Truck (F60H)
Read more
- Capacity 13,000 -19,600 lbs.
- Load Center 24″.
- Voltage 96V.
- Travel speed 11.18 mph.
Max Metal Needle Detector (MAX-k688)
Read more
- Detecting height ≤120mm.
- Detecting sensitivity 600mm(W)×100mm-200mm(L).
- Detecting Method Fe ¢0.8mm×1.2mm(K688s/K688D).
- Power requirements AC220V ± 10% (50-60Hz).
Hanna Portable Dissolved Oxygen Meter (HI9142)
Read more
- Dissolved Oxygen Accuracy ±1.5% F.S.
- Dissolved Oxygen Measurement Type polarographic.
- Dissolved Oxygen Range 0.0 to 19.9 mg/L (ppm).
- Dissolved Oxygen Resolution 0.1 mg/L (ppm).
- Dissolved Oxygen Accuracy ±1.5% F.S.
TOHO 15 Ton Chain Block (622A-15)
Read more
- Capacity 15ton/15000kg.
- Standard lift 3m.
- Running test load 175KN.
- Effort required to lift rated load 410.
TOHO 5 Ton Chain Block (622A-5)
Read more
- Capacity 5ton/5000kg.
- Standard lift 3m.
- Running test load 75KN.
- Effort required to lift rated load 400.
uMeasure 60M Intelligent Laser Distance Meter (MS6-60)
Read more
- Measure range 60m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
Hanna Three Range Portable TDS Meter (HI8734)
Read more
- TDS Accuracy ±1% FS .
- TDS Range 0.0 to 199.9 mg/L (ppm).
- TDS Resolution 0.1 mg/L (ppm).
- TDS Calibration manual, one-point through TDS knob.
T-Scale 2000KG Animal Cow Weight Scale (TF-1020-2T-M)
Read more
- Accuracy 500g.
- Capacity 5Kg~2000kg.
- Dimensions (W x L) 1000 x 2000mm.
- Operate Temperature -10℃~ 40℃.
G-Won Grain Moisture Meter (GMK-303RS)
Read more
- Accuracy ± 0.5 %.
- Resolution 0.1 %.
- Operation Temperature -10 ℃ ~ 40 ℃.
- Weight Approx. 1.5㎏.
uMeasure 40M Laser Distance Meter (MS-40A)
Read more
- Range 40m/ 120-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.

Reviews
There are no reviews yet.