Fluke 117 Electrician’s Multimeter with Non-Contact Voltage (117)
- Operating temperature -10°C to 50°C.
- Storage temperature -40°C to 60°C.
- Battery type 9 volt Alkaline, IEC 6LR61.
- Battery life 400 hours typical, without backlight.

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage (117)
Request a Call Back
- Ask a Question

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage (117)
Ask a Question
The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for Resistance, Continuity, Frequency, Capacitance, Min/Max/Average.
FEATURES OF 117 ELECTRICIAN’S MULTIMETER WITH NON-CONTACT VOLTAGE (117)
- Compact, true-rms digital multimeter for electricians.
- Includes multimeter, 4mm silicone test leads, holster and manual.
- Integrated non-contact voltage detection keeps you safe.
- Prevent false readings from ghost voltage with selectable low-impedance mode.
SPECIFICATION OF 117 ELECTRICIAN’S MULTIMETER WITH NON-CONTACT VOLTAGE (117)
| Name | Details | |
| Model | 117 | |
| Brand | Fluke | |
| Origin | Japan | |
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600V | |
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to 50°C | |
| Storage temperature | -40°C to 60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] [counts]): 0.5% 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V |
| Accuracy | ±([% of reading] [counts]): 0.5% 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% 3 (DC, 45 Hz to 500 Hz)4.0% 3 (500 Hz to 1 kHz) | |
| AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) | |
| AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
| Accuracy | 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer. | |
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF |
| Accuracy | 1.9% 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% 2 typical | |
| AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A10.00 A / 0.01 A |
| Accuracy | 1.5% 320 A continuous overload for 30 seconds max | |
| DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% 320 A continuous overload for 30 seconds max | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Based on 0 reviews
0.00
Overall
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
Be the first to review “Fluke 117 Electrician’s Multimeter with Non-Contact Voltage (117)” Cancel reply
SKU: STE0155
Category: New Bangladesh
Close
Categories
- Agriculture Equipment
- Business & Industry
- Electrical & Electronics
- Garments Machinery
- Meter Equipment
- Ammonia Gas Detector
- Anemometer
- Carbon Dioxide Detector
- Carbon Monoxide Detector
- Carbon Monoxide Meter
- Clamp Meter
- Coating Thickness Gauge
- Conductivity Meter
- Differential Pressure Meter
- Digital Multimeter
- Digital Tachometer
- Digital Thermometer
- Film Thickness Gauge
- Gas Detector
- Gas Leak Detector
- Gas Monitor
- Grain Moisture Meter
- Humidity Temperature Meter
- Infrared Thermal Imager
- Infrared Thermometer
- Insulation Resistance Tester
- Laser Distance Meter
- Lux Meter
- Metal Detector
- Moisture Meter
- Oxygen Monitor
- PH Meter
- Sound Level Meter
- TDS Meter
- Ultrasonic Thickness Gauge
- Underground Metal Detector
- Vibration Meter
- Voltage Detector
- Wood Moisture Meter
- Office Equipment
- Print and Packaging
- Safety Equipment
- Boiler Suit
- Eye Wash Station
- Fire Extinguisher
- Floor Sweeper
- Hand Gloves
- Hand Traffic Light
- Industrial Spill Kit
- Life Buoy Ring
- Marking Tape
- Metal Detector
- Road Con
- Safety Belt
- Safety Cabinet
- Safety Ear Muff
- Safety Goggles
- Safety Helmet
- Safety Mask
- Safety Shoe
- Safety Shower
- Search Mirror
- Spill Pallet
- Textile Lab Machinery
- Weight Scale and Balance
- Fashion & Beauty
- Food & Essentials
- Hobbies, Sports & Kids
- Home & Living
- Home & Property
- Mobile & Electronics
- Pet & Animals
- Vehicle & Parts
Tags
- Artificial Models
- Beakers
- Biofloc Equipment List
- Biofloc Solution
- Buffer Solution
- Calipers
- Clamp Meters
- Conductivity Meter
- Conical Flask
- Digital Balance
- Digital Humidity Meter
- Digital PH Meter
- Digital Weighing Scale
- EC Meter
- Garments and Textile
- General ICs
- Glass Beaker
- Glass Bottle
- Glass Conical Flask
- Glass Magnifier
- Glass Measuring Cylinder
- Hand Gloves
- IC
- Integrated Circuits
- Lab Chemicals
- Lab Cylinder
- Lab Glassware
- Lab Reagents
- Laser Distance Meter
- Magnifying Glasses
- Measuring Cylinder
- Multimeters
- PH Meters
- PH Tester
- Reagent Bottle
- Safe and Safety
- Slide Calipers
- TDS Meters
- TDS Tester
- Temperature Meter
- Transistors
- Vernier Caliper
- Water Multi-Parameter
- Water Technology & Research
- Water Test Kit
Related Products
Hanna Combo PH/Conductivity/TDS Tester (HI98130)
Read more
- pH Range 0.0 to 14.0 pH.
- pH Resolution 0.01 pH.
- pH Accuracy ±0.05 pH.
- pH Temperature Compensation automatic.
uMeasure 100M Laser Distance Meter (MS-100A)
Read more
- Range 100m/ 328-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.
uMeasure 40M Laser Distance Meter (MS-40A)
Read more
- Range 40m/ 120-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.
Hanna Three Range Portable TDS Meter (HI8734)
Read more
- TDS Accuracy ±1% FS .
- TDS Range 0.0 to 199.9 mg/L (ppm).
- TDS Resolution 0.1 mg/L (ppm).
- TDS Calibration manual, one-point through TDS knob.
Hanna Edge® Dedicated Dissolved Oxygen Meter (HI2004)
Read more
- Temperature Range -20.0 to 120.0 ºC ; -4.0 to 248.0 °F**.
- Temperature Resolution 0.1 ºC; 0.1 ºF.
- Temperature Accuracy ±0.5 °C, ±0.9 °F.
- DO Probe HI764080 (included).
Mileseey 1500M Telescope Laser Distance Meter (PF3S)
Read more
- Accuracy ± 5m.
- Measuring Range 1500 Meter.
- Angle range -45 ° ~ 45 ° Angle range.
- Measuring Unit M, Yd.
T-Scale 2000KG Animal Cow Weight Scale (TF-1020-2T-M)
Read more
- Accuracy 500g.
- Capacity 5Kg~2000kg.
- Dimensions (W x L) 1000 x 2000mm.
- Operate Temperature -10℃~ 40℃.
uMeasure 60M Intelligent Laser Distance Meter (MS6-60)
Read more
- Measure range 60m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
Hanna PH Meter Multiparameter (HI2020)
Read more
- pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV.
- pH Temperature Compensation ATC.
- pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV.
- pH Resolution 0.001 pH, 0.01 pH, 0.1 mV.
Hanna Edge® Dedicated Conductivity/TDS/Salinity Meter (HI2003)
Read more
- Salinity (% NaCl) Calibration Single point witd HI 7037L Standard.
- Salinity (PSU) Range 2.00 to 42.00 PSU.
- Salinity (PSU) Resolution 0.01 PSU.
- Salinity (PSU) Accuracy ±1% of reading.
Max Metal Needle Detector (MAX-k688)
Read more
- Detecting height ≤120mm.
- Detecting sensitivity 600mm(W)×100mm-200mm(L).
- Detecting Method Fe ¢0.8mm×1.2mm(K688s/K688D).
- Power requirements AC220V ± 10% (50-60Hz).
uMeasure 60M Laser Distance Meter (MS-60A)
Read more
- Range 60m/ 185 ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure.
- Unit m/in/ft.

Reviews
There are no reviews yet.