Fluke 87V Industrial Multimeter (87V)
- Operating temperature –20 °C to 55 °C.
- Storage temperature –40 °C to 60 °C.
- Humidity (without condensation) 0% – 90% (0 °C – 35 °C).
- Operating Altitude 2000 m.

Fluke 87V Industrial Multimeter (87V)
Request a Call Back
- Ask a Question

Fluke 87V Industrial Multimeter (87V)
Ask a Question
The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment – even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
- Easy-access door for fast battery changes without breaking the calibration seal
- Analog bar graph for fast changing or unstable signals
- Large digit display with bright, two-level backlight for easier reading in low light
- Touch Hold keeps readings on display even after removing probes
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
FEATURES OF 87V INDUSTRIAL MULTIMETER (87V)
- Identify complex signal problems fast.
- Supports accurate measurements on VFDs using a low-pass filter.
- Captures intermittents as fast as 250 µS with Peak Capture.
SPECIFICATION OF 87V INDUSTRIAL MULTIMETER (87V)
| Name | Details | |
| Model | 87V | |
| Brand | Fluke | |
| Origin | Japan | |
| Specifications | ||
| Voltage DC | Maximum voltage | 1000 V |
| Accuracy | ±(0.05% 1) | |
| Maximum resolution | 10 µV | |
| Voltage AC | Maximum voltage | 1000 V |
| Accuracy | ±(0.7% 2) True RMS | |
| AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
| Maximum resolution | 0.1 mV | |
| Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(0.2% 2) | |
| Maximum resolution | 0.01 µA | |
| Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(1.0% 2) True RMS | |
| Maximum resolution | 0.1 µA | |
| Resistance | Maximum resistance | 50 MΩ |
| Accuracy | ±(0.2% 1) | |
| Maximum resolution | 0.1 Ω | |
| Capacitance | Maximum capacitance | 9,999 µF |
| accuracy | ±(1% 2) | |
| Maximum resolution | 0.01 nF | |
| Frequency | Maximum frequency | 200 kHz |
| Accuracy | ±(0.005% 1) | |
| Maximum resolution | 0.01 Hz | |
| Duty cycle | Maximum duty cycle | 99.9% |
| Accuracy | ±(0.2% per kHz 0.1%) | |
| Maximum resolution | 0.1% | |
| Temperature measurement | –200.0 °C – 1090 °C–328.0 °F – 1994.0 °Fexcluding probe | |
| 80 BK temperature probe | –40.0 °C – 260 °C–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater | |
| Conductance | Maximum conductance | 60.00 nS |
| Accuracy | ±(1.0% 10) | |
| Maximum resolution | 0.01 nS | |
| Diode | Range | 3 V |
| Resolution | 1 mV | |
| Accuracy | ±(2% 1) | |
| Duty cycle range | Accuracy | Within ±(0.2% per kHz 0.1%) |
| Environmental Specifications | ||
| Operating temperature | –20 °C to 55 °C | |
| Storage temperature | –40 °C to 60 °C | |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C)0% – 70% (35 °C – 55 °C) | |
| Operating Altitude | 2000 m | |
| Safety Specifications | ||
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
| Agency approvals | CE, CSA, RCM | |
| Mechanical and General Specifications | ||
| Size | 201 x 98 x 52 mm (with holster) | |
| Weight | 355 g624 g – with holster | |
| Display | Digital | 6000 counts updates 4/sec.19,999 counts in high–resolution mode |
| Analog | 32 segments, updates 40/sec | |
| Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
| Warranty | Lifetime | |
| Battery Life | Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 | |
| Vibration | Per MIL–PRF–28800 for a Class 2 instrument | |
Based on 0 reviews
0.00
Overall
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
Be the first to review “Fluke 87V Industrial Multimeter (87V)” Cancel reply
SKU: STE0161
Category: New Bangladesh
Close
Categories
- Agriculture Equipment
- Business & Industry
- Electrical & Electronics
- Garments Machinery
- Meter Equipment
- Ammonia Gas Detector
- Anemometer
- Carbon Dioxide Detector
- Carbon Monoxide Detector
- Carbon Monoxide Meter
- Clamp Meter
- Coating Thickness Gauge
- Conductivity Meter
- Differential Pressure Meter
- Digital Multimeter
- Digital Tachometer
- Digital Thermometer
- Film Thickness Gauge
- Gas Detector
- Gas Leak Detector
- Gas Monitor
- Grain Moisture Meter
- Humidity Temperature Meter
- Infrared Thermal Imager
- Infrared Thermometer
- Insulation Resistance Tester
- Laser Distance Meter
- Lux Meter
- Metal Detector
- Moisture Meter
- Oxygen Monitor
- PH Meter
- Sound Level Meter
- TDS Meter
- Ultrasonic Thickness Gauge
- Underground Metal Detector
- Vibration Meter
- Voltage Detector
- Wood Moisture Meter
- Office Equipment
- Print and Packaging
- Safety Equipment
- Boiler Suit
- Eye Wash Station
- Fire Extinguisher
- Floor Sweeper
- Hand Gloves
- Hand Traffic Light
- Industrial Spill Kit
- Life Buoy Ring
- Marking Tape
- Metal Detector
- Road Con
- Safety Belt
- Safety Cabinet
- Safety Ear Muff
- Safety Goggles
- Safety Helmet
- Safety Mask
- Safety Shoe
- Safety Shower
- Search Mirror
- Spill Pallet
- Textile Lab Machinery
- Weight Scale and Balance
- Fashion & Beauty
- Food & Essentials
- Hobbies, Sports & Kids
- Home & Living
- Home & Property
- Mobile & Electronics
- Pet & Animals
- Vehicle & Parts
Tags
- Artificial Models
- Beakers
- Biofloc Equipment List
- Biofloc Solution
- Buffer Solution
- Calipers
- Clamp Meters
- Conductivity Meter
- Conical Flask
- Digital Balance
- Digital Humidity Meter
- Digital PH Meter
- Digital Weighing Scale
- EC Meter
- Garments and Textile
- General ICs
- Glass Beaker
- Glass Bottle
- Glass Conical Flask
- Glass Magnifier
- Glass Measuring Cylinder
- Hand Gloves
- IC
- Integrated Circuits
- Lab Chemicals
- Lab Cylinder
- Lab Glassware
- Lab Reagents
- Laser Distance Meter
- Magnifying Glasses
- Measuring Cylinder
- Multimeters
- PH Meters
- PH Tester
- Reagent Bottle
- Safe and Safety
- Slide Calipers
- TDS Meters
- TDS Tester
- Temperature Meter
- Transistors
- Vernier Caliper
- Water Multi-Parameter
- Water Technology & Research
- Water Test Kit
Related Products
Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Read more
- EC Accuracy ±1% of reading.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.
HASHIMA Hand Type Needle Detector (HN-30)
Read more
- Detecting Level 2 steps.
- Detecting Area 25(W)×50(D)mm.
- Alarm Method Buzzer, LED lamp.
- Detecting Method Magnet induction system.
Hanna Edge® EC/TDS/Salinity Multiparameter (HI2030)
Read more
- EC Accuracy ±1% of reading
- pH Resolution 0.01 pH, 0.001 pH*
- pH Accuracy ±0.01pH, ±0.002 pH*.
- pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*.
uMeasure 100M Laser Distance Meter (MS-100A)
Read more
- Range 100m/ 328-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.
uMeasure 40M Laser Distance Meter (MS-40A)
Read more
- Range 40m/ 120-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.
uMeasure 60M Intelligent Laser Distance Meter (MS6-60)
Read more
- Measure range 60m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
TOHO 15 Ton Chain Block (622A-15)
Read more
- Capacity 15ton/15000kg.
- Standard lift 3m.
- Running test load 175KN.
- Effort required to lift rated load 410.
Hanna Waterproof TDS Tester (HI98301)
Read more
- EC to TDS Conversion Factor 0.5.
- Temperature Range 0.0 to 50.0°C (32.0 to 122.0°F).
- Temperature Resolution 0.1°C (0.1°F).
- Temperature Accuracy ±0.5°C (±1°F).
Hanna Combo PH/Conductivity/TDS Tester (HI98130)
Read more
- pH Range 0.0 to 14.0 pH.
- pH Resolution 0.01 pH.
- pH Accuracy ±0.05 pH.
- pH Temperature Compensation automatic.
CARER Electric Forklift Truck (F60H)
Read more
- Capacity 13,000 -19,600 lbs.
- Load Center 24″.
- Voltage 96V.
- Travel speed 11.18 mph.
Hanna Edge® Dedicated Conductivity/TDS/Salinity Meter (HI2003)
Read more
- Salinity (% NaCl) Calibration Single point witd HI 7037L Standard.
- Salinity (PSU) Range 2.00 to 42.00 PSU.
- Salinity (PSU) Resolution 0.01 PSU.
- Salinity (PSU) Accuracy ±1% of reading.
Max Metal Needle Detector (MAX-k688)
Read more
- Detecting height ≤120mm.
- Detecting sensitivity 600mm(W)×100mm-200mm(L).
- Detecting Method Fe ¢0.8mm×1.2mm(K688s/K688D).
- Power requirements AC220V ± 10% (50-60Hz).

Reviews
There are no reviews yet.