KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
- Accuracy Within ±1.0 SPAD units .
- Repeatability Within ±0.3 SPAD units.
- Display LCD panel showing 4-digit measurement value .
- Display range -9.9 to 199.9 SPAD units.

KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
Request a Call Back
- Ask a Question

KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
Ask a Question
The SPAD-502Plus enables quick, easy measurement of the chlorophyll content of plant leaves without damaging the leaf. Chlorophyll content is one indicator of plant health, and can be used to optimize the timing and quantity of applying additional fertilizer to provide larger crop yields of higher quality with lower environmental load.
FEATURES OF MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
- Measurement method Optical density difference at two wavelengths.
- Measurement area 2 mm×3 mm.
- Subject thickness 1.2 mm maximum.
- Subject insertion depth 12 mm (with stopper having position adjustable from 0 to 6 mm).
- Light source 2 LED elements.
- Receptor 1 SPD (silicon photodiode).
- Display LCD panel showing 4-digit measurement value .
- Display range -9.9 to 199.9 SPAD units.
- Memory function Memory capacity for up to 30 values; Calculation/display of average of data in memory also possible.
- Power source 2 AA-size alkaline batteries
- Battery life More than 20,000 measurements (when using new alkaline batteries under Konica Minolta test conditions).
- Minimum interval between measurements Approx. 2 seconds.
- Accuracy Within ±1.0 SPAD units
- Repeatability Within ±0.3 SPAD units
- (SPAD value between 0.0 and 50.0 with no change in sample position).
- Dimensions 78 (W) ×164 (H) ×49 (D) mm.
- Weight 200 g (excluding batteries).
SPECIFICATION OF MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
| Name | Details |
| Model | SPAD-502Plus |
| Brand | KONICA MINOLTA |
| Origin | Japan |
| Measurement method | Optical density difference at two wavelengths. |
| Measurement area | 2 mm×3 mm. |
| Subject thickness | 1.2 mm maximum. |
| Subject insertion depth | 12 mm (with stopper having position adjustable from 0 to 6 mm). |
| Light source | 2 LED elements. |
| Receptor | 1 SPD (silicon photodiode). |
| Display | LCD panel showing 4-digit measurement value (values shown to first decimal place) and 2-digit number of measurements; Trend graph of values in memory can also be shown. |
| Display range | -9.9 to 199.9 SPAD units. |
| Memory function | Memory capacity for up to 30 values; Calculation/display of average of data in memory also possible. |
| Power source | 2 AA-size alkaline batteries |
| Battery life | More than 20,000 measurements (when using new alkaline batteries under Konica Minolta test conditions). |
| Minimum interval between measurements | Approx. 2 seconds. |
| Accuracy | Within ±1.0 SPAD units (for SPAD value between 0.0 and 50.0 under normal temperature/humidity)“*” added to display when measurement exceeds 50.0 SPAD units. |
| Repeatability | Within ±0.3 SPAD units(SPAD value between 0.0 and 50.0 with no change in sample position). |
| Dimensions | 78 (W) ×164 (H) ×49 (D) mm. |
| Weight | 200 g (excluding batteries). |
Based on 0 reviews
0.00
Overall
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
Be the first to review “KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)” Cancel reply
Close
Categories
- Agriculture Equipment
- Business & Industry
- Electrical & Electronics
- Garments Machinery
- Lifting Equipment
- Meter Equipment
- Ammonia Gas Detector
- Anemometer
- Carbon Dioxide Detector
- Carbon Monoxide Detector
- Carbon Monoxide Meter
- Clamp Meter
- Coating Thickness Gauge
- Conductivity Meter
- Differential Pressure Meter
- Digital Multimeter
- Digital Tachometer
- Digital Thermometer
- Film Thickness Gauge
- Gas Detector
- Gas Leak Detector
- Gas Monitor
- Grain Moisture Meter
- Humidity Temperature Meter
- Infrared Thermal Imager
- Infrared Thermometer
- Insulation Resistance Tester
- Laser Distance Meter
- Lux Meter
- Metal Detector
- Moisture Meter
- Oxygen Monitor
- PH Meter
- Sound Level Meter
- TDS Meter
- Ultrasonic Thickness Gauge
- Underground Metal Detector
- Vibration Meter
- Voltage Detector
- Wood Moisture Meter
- Office Equipment
- Print and Packaging
- Safety Equipment
- Boiler Suit
- Eye Wash Station
- Fire Extinguisher
- Floor Sweeper
- Hand Gloves
- Hand Traffic Light
- Industrial Spill Kit
- Life Buoy Ring
- Marking Tape
- Metal Detector
- Road Con
- Safety Belt
- Safety Cabinet
- Safety Ear Muff
- Safety Goggles
- Safety Helmet
- Safety Mask
- Safety Shoes
- Safety Shower
- Search Mirror
- Spill Pallet
- Textile Lab Machinery
- Weight Scale and Balance
- Fashion & Beauty
- Food & Essentials
- Hobbies, Sports & Kids
- Home & Living
- Home & Property
- Mobile & Electronics
- Pet & Animals
- Vehicle & Parts
Tags
- Aeropak
- Artificial Models
- Beakers
- Biofloc Equipment List
- Biofloc Solution
- Buffer Solution
- Calipers
- Clamp Meters
- Conductivity Meter
- Conical Flask
- Digital Balance
- Digital Humidity Meter
- Digital PH Meter
- Digital Weighing Scale
- EC Meter
- Garments and Textile
- General ICs
- Glass Beaker
- Glass Bottle
- Glass Conical Flask
- Glass Magnifier
- Glass Measuring Cylinder
- Hand Gloves
- IC
- Integrated Circuits
- Lab Chemicals
- Lab Cylinder
- Lab Glassware
- Lab Reagents
- Laser Distance Meter
- Magnifying Glasses
- Measuring Cylinder
- Multimeters
- PH Meters
- PH Tester
- Reagent Bottle
- Safe and Safety
- Slide Calipers
- TDS Meters
- TDS Tester
- Temperature Meter
- Transistors
- Vernier Caliper
- Water Multi-Parameter
- Water Technology & Research
Related Products
uMeasure 60M Intelligent Laser Distance Meter (MS6-60)
Read more
- Measure range 60m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
uMeasure 100M Laser Distance Meter (MS-100A)
Read more
- Range 100m/ 328-ft.
- Accuracy ±1.5mm 1/16 in.
- Single measure .
- Unit m/in/ft.
T-Scale 2000KG Animal Cow Weight Scale (TF-1020-2T)
Read more
- Accuracy 500g.
- Capacity 5Kg~2000kg.
- Dimensions (W x L) 1000 x 2000mm.
- Operate Temperature -10℃~ 40℃.
G-Won Grain Moisture Meter (GMK-303RS)
Read more
- Accuracy ± 0.5 %.
- Resolution 0.1 %.
- Operation Temperature -10 ℃ ~ 40 ℃.
- Weight Approx. 1.5㎏.
uMeasure 80M Laser Distance Meter (MS-80A)
Read more
- Range 80m/ 245-ft.
- Accuracy ±1.5mm 1/16 in.
- Unit m/in/ft.
- Laser Class Class 2M Ⅱ.
T-Scale 2000KG Animal Cow Weight Scale (TF-1020-2T-M)
Read more
- Accuracy 500g.
- Capacity 5Kg~2000kg.
- Dimensions (W x L) 1000 x 2000mm.
- Operate Temperature -10℃~ 40℃.
Hanna Waterproof TDS Tester (HI98301)
Read more
- EC to TDS Conversion Factor 0.5.
- Temperature Range 0.0 to 50.0°C (32.0 to 122.0°F).
- Temperature Resolution 0.1°C (0.1°F).
- Temperature Accuracy ±0.5°C (±1°F).
HASHIMA Hand Type Needle Detector (HN-30)
Read more
- Detecting Level 2 steps.
- Detecting Area 25(W)×50(D)mm.
- Alarm Method Buzzer, LED lamp.
- Detecting Method Magnet induction system.
Hanna PH Meter Multiparameter (HI2020)
Read more
- pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV.
- pH Temperature Compensation ATC.
- pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV.
- pH Resolution 0.001 pH, 0.01 pH, 0.1 mV.
uMeasure 80M Intelligent Laser Distance Meter (MS6-80)
Read more
- Measure range 80m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Read more
- EC Accuracy ±1% of reading.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.
TOHO 5 Ton Chain Block (622A-5)
Read more
- Capacity 5ton/5000kg.
- Standard lift 3m.
- Running test load 75KN.
- Effort required to lift rated load 400.

Reviews
There are no reviews yet.