Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
- EC Accuracy ±1% of reading.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.

Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Request a Call Back
- Ask a Question

Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Ask a Question
The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.HI98192 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.HI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.
FEATURES OF EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
- EC Accuracy ±1% of reading
- EC Calibration automatic up to five points with seven memorized standards
- TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L).
- TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L).
- TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater).
- EC/TDS Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F).
- Temperature Correction Coefficient 0.00 to 10.00 %/°C.
- EC to TDS Conversion Factor 0.40 to 1.00.
- Reference Temperature 15°C, 20°C and 25°C.
- EC/TDS Multi-range Measurement Modes autorange, autoend, lock and fixed range.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.
- Salinity (% NaCl) Calibration max. one point only in % range (with HI7037 standard).
- Salinity (PSU) Range 0.00 to 42.00 (PSU).
- Salinity (PSU) Resolution 0.01 PSU.
- Salinity (PSU) Accuracy ±1% of reading.
- Salinity (PSU) Calibration based on conductivity calibration.
- Salinity Range 0.00 to 80.00 (ppt).
- Salinity Resolution (ppt) 0.01 ppt.
- Salinity Accuracy (ppt) ±1% of reading.
- Salinity Calibration (ppt) based on conductivity calibration.
SPECIFICATION OF EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
| Name | Details |
|---|---|
| Model: | HI98192 |
| Brand: | Hanna |
| Origin: | Romania |
| Product Name: | Waterproof Portable EC/TDS/Resistivity/Salinity Meter – HI98192. |
| Quote Required: | Yes. |
| EC Range: | 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm) |
| EC Resolution: | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm. |
| EC Accuracy: | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater). |
| EC Calibration: | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm). |
| TDS Range: | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L). |
| TDS Resolution: | 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L). |
| TDS Accuracy: | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater). |
| EC/TDS Temperature Compensation: | noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F). |
| Temperature Correction Coefficient: | 0.00 to 10.00 %/°C. |
| EC to TDS Conversion Factor: | 0.40 to 1.00. |
| Reference Temperature: | 15°C, 20°C and 25°C. |
| EC/TDS Multi-range Measurement Modes: | autorange, autoend, lock and fixed range. |
| Salinity (% NaCl) Range: | 0.0 to 400.0%. |
| Salinity (% NaCl) Resolution: | 0.1%. |
| Salinity (% NaCl) Accuracy: | ±1% of reading. |
| Salinity (% NaCl) Calibration: | max. one point only in % range (with HI7037 standard). |
| Salinity (PSU) Range: | 0.00 to 42.00 (PSU). |
| Salinity (PSU) Resolution: | 0.01 PSU. |
| Salinity (PSU) Accuracy: | ±1% of reading. |
| Salinity (PSU) Calibration: | based on conductivity calibration. |
| Salinity Range: | 0.00 to 80.00 (ppt). |
| Salinity Resolution (ppt): | 0.01 ppt. |
| Salinity Accuracy (ppt): | ±1% of reading. |
| Salinity Calibration (ppt): | based on conductivity calibration. |
| Resistivity Range: | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm. |
| Resistivity Resolution: | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*. |
| Resistivity Accuracy: | ±1% of reading (±10 Ω or 1 digit, whichever is greater). |
| Temperature Range: | -20.0 to 120.0°C (-4.0 to 248.0°F). |
| Temperature Resolution: | 0.1°C (0.1°F). |
| Temperature Accuracy: | ±0.2°C; ±0.4°F (excluding probe error). |
| EC/TDS Probe: | HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included). |
| Logging Type: | Log-on-demand. |
| Logging Memory: | up to 10. |
| Connectivity: | opto-isolated USB with optional HI 92000 software and micro USB cable. |
| Automatic Shut-Off: | user selectable. |
| Battery Type/Life: | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight. |
| Environment: | 0 to 50°C (32 to 122°F); RH 100% (IP67). |
| Dimensions: | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”). |
| Weight: | 400 g (14.2 oz.). |
| Ordering Information: | HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. |
| Notes: | The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe. |
Based on 0 reviews
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
|
|
|
0% |
- Agriculture Equipment
- Business & Industry
- Electrical & Electronics
- Garments Machinery
- Lifting Equipment
- Meter Equipment
- Ammonia Gas Detector
- Anemometer
- Carbon Dioxide Detector
- Carbon Monoxide Detector
- Carbon Monoxide Meter
- Clamp Meter
- Coating Thickness Gauge
- Conductivity Meter
- Differential Pressure Meter
- Digital Multimeter
- Digital Tachometer
- Digital Thermometer
- Film Thickness Gauge
- Gas Detector
- Gas Leak Detector
- Gas Monitor
- Grain Moisture Meter
- Humidity Temperature Meter
- Infrared Thermal Imager
- Infrared Thermometer
- Insulation Resistance Tester
- Laser Distance Meter
- Lux Meter
- Metal Detector
- Moisture Meter
- Oxygen Monitor
- PH Meter
- Sound Level Meter
- TDS Meter
- Ultrasonic Thickness Gauge
- Underground Metal Detector
- Vibration Meter
- Voltage Detector
- Wood Moisture Meter
- Office Equipment
- Print and Packaging
- Safety Equipment
- Boiler Suit
- Eye Wash Station
- Fire Extinguisher
- Floor Sweeper
- Hand Gloves
- Hand Traffic Light
- Industrial Spill Kit
- Life Buoy Ring
- Marking Tape
- Metal Detector
- Road Con
- Safety Belt
- Safety Cabinet
- Safety Ear Muff
- Safety Goggles
- Safety Helmet
- Safety Mask
- Safety Shoes
- Safety Shower
- Search Mirror
- Spill Pallet
- Textile Lab Machinery
- Weight Scale and Balance
- Fashion & Beauty
- Food & Essentials
- Hobbies, Sports & Kids
- Home & Living
- Home & Property
- Mobile & Electronics
- Pet & Animals
- Vehicle & Parts
- Best Distance Meter
- Best Laser Distance Meter
- Digital Distance Measure
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Distance Device
- Distance Measuring Meter
- Distance Meter
- Handheld Laser Measure
- Hanna TDS Meter
- IR thermometer
- Laser Beam Distance Measurement
- Laser Distance Detector
- Laser Distance Measurer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Measurement
- Laser Length Meter
- Laser Light Distance Measurement
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Outdoor Laser Measuring Device
- Portable Laser Distance Meter
- Range Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Accuracy 500g.
- Capacity 5Kg~2000kg.
- Dimensions (W x L) 1000 x 2000mm.
- Operate Temperature -10℃~ 40℃.
- Measuring Error ±3%F.S. /-1 digit.
- Temperature Accuracy ±1°C.
- TDS Measuring Range 0ppm-1999ppm.
- Conductivity Measuring Range 0 μS-1999 μS.
- pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV.
- pH Temperature Compensation ATC.
- pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV.
- pH Resolution 0.001 pH, 0.01 pH, 0.1 mV.
- EC Accuracy ±1% of reading
- pH Resolution 0.01 pH, 0.001 pH*
- pH Accuracy ±0.01pH, ±0.002 pH*.
- pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*.
- Range 80m/ 245-ft.
- Accuracy ±1.5mm 1/16 in.
- Unit m/in/ft.
- Laser Class Class 2M Ⅱ.
- Measuring Range(m) 100m.
- Record Data 50 Values.
- Operation Temperature 0°C- 40°C(32°F – 104°F).
- Storage Temperature -10°C- 60°Cr-141 – 140T).
- Measure range 60m.
- Measure unit m/ft/in.
- Accuracy ±1.5mm.
- Storage temperature -10°C~60°C.
- TDS Accuracy ±1% FS .
- TDS Range 0.0 to 199.9 mg/L (ppm).
- TDS Resolution 0.1 mg/L (ppm).
- TDS Calibration manual, one-point through TDS knob.
- Testing Range 10KΩ~20GΩ
- ACV Accuracy ( 2%dgt 15rdg )
- ACV Frequency 50/60Hz
- Operating Condition 0~40℃, < 80%RH
- Measuring Range 328ft /100m.
- Distance Measurement Precision ±1/16.
- Units m / in / ft / ft in.
- Max storage 20 units.
- Capacity 13,000 -19,600 lbs.
- Load Center 24″.
- Voltage 96V.
- Travel speed 11.18 mph.
- Temperature Range -20.0 to 120.0 ºC ; -4.0 to 248.0 °F**.
- Temperature Resolution 0.1 ºC; 0.1 ºF.
- Temperature Accuracy ±0.5 °C, ±0.9 °F.
- DO Probe HI764080 (included).




Reviews
There are no reviews yet.