ST4203 DC Resistance Tester

৳ 0.00

+ −
  • Placeholder

    ST4203 DC Resistance Tester

    ৳ 0.00

    Request a Call Back

    •  Ask a Question
      Placeholder

      ST4203 DC Resistance Tester

      ৳ 0.00

      Ask a Question


      Temperature Measurement Accuracy

      Type Range Maximum display Resolution Test accuracy
      Temp probe -10.0℃~60.0℃ 60.0℃ 0.1℃ ±1.0℃
      Temp probe -10.0℃~60.0℃ 60.0℃ 0.2℃ ±1.0℃

      Resistance Measurement Accuracy

      Measuring current Measuring range Precision Resolution
      20A 10.0uΩ~1000.0uΩ ±0.2%FS±10dgt 0.1uΩ
      1.000mΩ~10.000mΩ ±0.2%FS±10dgt 0.001mΩ
      10A 10.00mΩ~100.00mΩ ±0.2%FS±10dgt 0.01mΩ
      5A 100.0mΩ~1000.0mΩ ±0.2%FS±10dgt 0.1mΩ
      1A 1.000Ω~10.000Ω ±0.2%FS±10dgt 0.001Ω
      0.1A 10.00Ω~100.00Ω ±0.2%FS±10dgt 0.01Ω
      10mA 100.0Ω~1000.0Ω ±0.2%FS±10dgt 0.1Ω
      1mA 1.000KΩ~10.000KΩ ±0.4%FS±30dgt 0.001KΩ
      10.00KΩ~100.00KΩ ±0.4%FS±30dgt 0.01KΩ
      100.0KΩ~1000.0KΩ ±1.5%FS±50dgt 0.1KΩ
      Temperature characteristics: plus test accuracy × 0.3/°C within the operating temperature range. (outside 18°C to 28°C)
      Calculation method: accuracy = (accuracy of current gear) + 0.3×(number of temperature difference)×(accuracy of current gear)
      Example: use the environment 8°C/20A current file, the accuracy of this file is ±0.2%FS±10dgt
      Accuracy = (0.2%FS±10dgt) + 0.3×10×(0.2%FS±10dgt) = 0.8%FS±40dgt
      (Note: 1mA current 1000K gear test accuracy is only valid at 18°C to 28°C)
      Long-term testing of high-current gears is prone to heating and affecting accuracy. If there is any deviation, you need to wait for a while before testing.

      Technical specifications

      Function It is mainly used to measure transformer DC resistance, transformer winding resistance, ground grid connection continuity, cable wire resistance, switch, connector, relay contact resistance, coil, motor, transformer winding resistance and metal riveting resistance, metal components Interconnection resistance test, low value resistance test, contact resistance test, etc.
      Sample type Optional Cu copper, Al aluminum, Fe iron, Au gold, Ag silver material
      Resistance Range 10.0uΩ-1000.0KΩ
      Resolution 0.1 uΩ
      Overflow display “OL” symbol display when over-range overflow
      Detection method Four-wire test
      Test current 20A、10A、5A、1A、0.1A、10mA、1mA
      Short circuit current 20A
      Temperature check Yes, external temperature probe, internal temperature sensor, dual sensor design
      Temperature conversion Yes, temperature conversion, can convert 75 ℃ measurement results
      Overload protection Have
      Automatic discharge Have
      Power DC14.6V  12000mAhLarge capacity lithium battery
      Charging function Have
      Display mode 5-inch touch screen (854dots×480dots) full-color LCD display
      Interactive mode Touch screen/button
      LCD size Length and width:108 mm×65mm
      Meter size Length width height:277.2mm×227.5mm×153mm
      Test line length 5 meters, 1 red and 1 black
      Mobile APP Have, Bluetooth connection
      Computer PC Have, USB cable connection
      Data storage 800 Groups
      Data review Data lookup function
      Printer There is a printer embedded in the instrument panel, press the print button to print the test results
      Battery voltage The battery power is displayed in real time, prompting that the battery needs to be charged in time when the voltage is low
      Automatic shut-down Optional off, 5 minutes, 10 minutes, 15 minutes, 20 minutes, 25 minutes, 30 minutes
      Power  Standby: about 4W (30% brightness)
      Consumption Measurement: 100W Max
      Quality Meter: 3.1kg (including battery)
      Test line: 850g
      Working temperature and humidity -10℃~40℃;70%rh  following
      Storage temperature and humidity -20℃~60℃;70%rh  following
      Insulation resistance More than 10MΩ (500V between the circuit and the shell)
      Pressure resistance AC 3700V/rms (between the circuit and the case)
      Suitable for safety regulations IEC61010-4-3, radio frequency electromagnetic field≤1V/m
      Suitable for safety regulations IEC61010-1, CAT Ⅲ 600V, pollution degree 2, JJG724-1991 “Verification Regulations for DC Digital Ohmmeter”, JJG166-1993 “Verification Regulations for DC Resistors”, “DL/T967-2005 Loop Resistance Tester and DC Resistance Fast Tester Verification Regulations”

       

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “ST4203 DC Resistance Tester”

      Your email address will not be published. Required fields are marked *

      Reviews

      There are no reviews yet.

      SKU: SSB-ST4203 Category:
      Close
      Close My Cart
      Close Wishlist
      Recently Viewed Close
      Close

      Close
      Navigation
      Categories